XY-TR01 Thermostat Temperature Humidity Sensor Thermometer Hygrometer Controller Module with LED Digital Display Dual Output DC6-30V XY-TR01 Thermostat Temperature Humidity Sensor Thermometer Hygrometer Controller Module with LED Digital Display Dual Output DC6-30V XY-TR01 Thermostat Temperature Humidity Sensor Thermometer Hygrometer Controller Module with LED Digital Display Dual Output DC6-30V



null
Specifications:

Temperature range:-20 ° C ~ 60 ° C
Humidity range:00%~ 100%RH
Control accuracy:0.1 °C 0.1% RHE
Output capacity:up to 10A
Size: 6x5.7cm/2.36x2.24inch

Function:

Product features are two main types of classification: the functions of temperature and humidity

Function of temperature are as follows:

The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode'C'.
Start temperature < stop temperature, heating mode 'H'.
Cooling mode:
When the temperature≥Start temperature,relay conduction,red led on, refrigeration equipment begin to work;
When the temperature≤Stop temperature,relay disconnect, red led off, refrigeration equipment stop to work;
Heating mode:
When the temperature≤Start temperature,relay conduction, red led on, heating equipment begin to work;
When the temperature≥Stop temperature,relay disconnect, red led off, heating equipment stop to work;
Temperature correction function OFE (-10.0 ~ 10℃):
       The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;

How to set the start/stop temperature:

1. In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface,can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;

 The humidity function is as follows:

The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity> stop humidity, dehumidificationmode'D'.
Start humidity< stop humidity, humidificationmode 'E'.
Dehumidificationmode:
When the humidity≥Start humidity,relay conduction, green led on, dehumidification equipment begin to work;
When the humidity≤Stophumidity,relay disconnect, green led off, dehumidificationequipment stop to work;
Humidificationmode:
When the humidity≤Start humidity,relay conduction, green led on, humidificationequipment begin to work;
When the humidity≥Stophumidity,relay disconnect, green led off, humidificationequipment stop to work;
Humidificationcorrection function RH (-10.0 ~ 10%):
       The system is working for a long time and may be biased, through this function correction, the actual humidity= measuring humidity+ calibration value;

How to set the start/stop humidity:

1.In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humiditysettings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
2.In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humiditysettings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;

Running Interface Description:  

Working mode shows that the current mode ("H/C", "E/d") will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed.   
Any relay conduction, the upper-left corner of the interface display "out", if the temperature relay conduction, the flashing display temperature working mode "H/C" to show reminders; if the humidity relay conduction, then flashing display humidity working mode "E/d", as a reminder;
Other features:
Parameter remote read/set:   
Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters;
temperature/Humidity Real-time reporting:
If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection;
Relay enabling (by default):
If the relay is disable, the relay remains disconnected;

How to modify the temperature/humidity correction value:

1.In the operating interface, double-click the ' TM+ ' key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE: Temperature correction value RH: Humidity correction value)
At this time by a short press ' TM-' key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short;
3.When the parameters have been modified, double-click the ' TM+ ' key, exit the correction positive setting interface, and save the data.

Package Included:

1 x XY-TR01 Thermometer Hygrometer Controller Module
1 x Sensor Cable